Steps to Console Redirection Setting via Megarac SP Java SOL
Equipment preparations: RJ45 Ethernet cable
Make sure RJ45 port plug into IPMI_LAN port on the server side board, the RJ45 port plug into general LAN port on client side.
Please follow the BIOS setting for the server side: Advanced→Serial Port Console Redirection→ SOL - Console Redirection: [Enable] - Console Redirection Settings: Bits per second: [115200]
Legacy Console Redirection - Legacy Serial Redirec: [SOL] Legacy Serial Redirec: [SOL]
Windows EMS - Console Redirection: [Enable] - Console Redirection Settings: Out-of-Band Mgmt Port: [SOL] Bits per second: [115200]
Megarac SP setting (client side): Remote Control→Java SOL
Click the [Java SOL]
NOTE: A compatible JRE must be installed in the system prior to the launch of the JNLP file.
Please follow the Java SOL setting, and click [Connect]. BMC IP: {Station IP address} Username: {Megarac SP login ID} ** “admin” in default Password: {Megarac SP login password} ** “admin” in default Volatile-Bit-Rate: [115.2K] Non-Volatile-Bit-Rate: [115.2K]
eboot server system and SOL has start working. SOL to BIOS